Model: RY-ELE HDR-60-24
Output: 24V 2.5A, 60W
Input: 85-264VAC, 47-63Hz (120-370VDC)
Typical Efficiency: >86% at 230VAC, rated load, 25°C
Ripple & Noise: <120mV
Protection: Overload 115%-135% hiccup mode; short-circuit auto-recovery
Withstand Voltage: Input-to-output 3KVAC for 1 minute
Compact Size: 92.5×54×29 mm
HDR-60-24 60W 24VDC 2.5A Ultra Slim DIN Rail Power Supply
Output: 24V DC, 0–2.5A (60W Max Output Power)
Input Range: 85–264VAC / 120–370VDC
Form Factor: 52.5mm (3SU) Ultra-Slim Plastic Housing
Efficiency: Up to 88% (230VAC)
Installation: Fits TS-35/7.5 or TS-35/15 DIN Rails
| Model Number | Output Voltage | Rated Current | Rated Power | Efficiency (Typ.) | Ripple & Noise |
| HDR-60-12 | 12V | 5A | 60W | >85% | <100mV |
| HDR-60-24 | 24V | 2.5A | 60W | >86% | <120mV |
| HDR-60-48 | 48V | 1.25A | 60W | >88% | <200mV |
Input
Voltage Range: 85-264VAC, 47Hz~63Hz (120VDC~370VDC)
Working Current: <1.2A at 110VAC / <0.8A at 220VAC
Inrush Current: 15A at 115VAC / 30A at 230VAC
Output
Rated Voltage: 24V
Rated Current: 2.5A
Rated Power: 60W
Voltage Accuracy: ±1%
Voltage Adjustment Range: ±10%
Load Regulation: ±1%
Line Regulation: ±1%
Startup, Rise, Hold-up Time: 100ms, 30ms, 21ms at 110VAC / 100ms, 30ms, 100ms at 220VAC
Protection & Environment
Overload Protection: 115%-135%, Hiccup mode, Auto-recovery
Short Circuit Protection: Output shutdown when +V0 drops to undervoltage point, Auto-recovery
Operating Temp & Humidity: -10℃~+50℃; 20%~90% RH
Storage Temp & Humidity: -20℃~+85℃; 10%~95% RH
Withstand Voltage: Input-Output: 3KVAC for 1 minute
Isolation Resistance: Input-Output, Input-Case, Output-Case: 500VDC/100MΩ
Dimensions & Weight
Dimensions: 92.5×54×29 mm
Net Weight / Gross Weight: 105g / 107g